Geiger Counter RADEX RD1706

Improvements of RADEX RD1706 comparing to the basic model RADEX RD1503 :

ability to register gamma, beta and x-ray radiation
expanded range of indications (up to 999,0 µSv/h)
time of observation is reduced from 1 to 26 sec.
time of observation gradually reduces from 26 to 1 sec. when the value of a dose rate is higher than 3,5 µSv/h
improved precision of indications
the ability to set threshold level indications up to 99,0 µSv/h (100 times in comparison with RADEX RD1503)
«BACKGROUND» mode for performing inspections inside premises using algorithm similar to methodical instructions МУ 2.6.1.715-98 Conducting a radiationally-hygienic inspection of inhabited and public buildings
displaying the value of a background dose rate
displaying the difference in indications between the average dose rate and a background dose rate
value of a background dose rate is saved after turning off the device
displaying an average dose rate exceeding over a background dose rate
vibra-call signal as the additional alarming function
possibility to regulate a vibra signal (turning on/off)

Technical and work specifications :

RADEX RD1706 evaluates the ambient equivalent of dose rate Н*(10) of gamma radiation with taking into account gamma radiation and the pollution of objects by sources of beta particles.
The device can be used by the population in day-to-day life (foodstuff, building materials, soil etc.) and by the personnel operating with ionizing radiation sources.
RADEX RD1706 evaluates the value of beta and gamma radiation by the means of two SBM20-1 type Gejgera  Muller counters and displays the indications in µSv/h on LCD. The time of observation a dose rate and varies from 40 to 26 seconds.
Registration of every particle is accompanied with a sound signal what makes it easer to search for the source of radiation.
The device possesses «BACKGROUND» mode which gives not just one but two indications. One stands for exceeding of a dose rate over a background dose rate, the second stands for a background dose rate. This mode is convenient for examining inside buildings, when it is necessary to know how indications indoors differ from the ones outdoors.

The device possesses next features: specification of indications in proportion of increase of monitoring time,
turning on/off display backlight,
turning on/off audio and vibra signals.

MENU titles can be translated in the language of the customer